30 SCOPIA 400/1000 Gateway User Guide
Installing the Gateway
Figure 2-5 Inserting the RTM Module in the SCOPIA 400
Chassis
7 Use even pressure to push the module further into the slot.
Caution Do not force the connection. Forcing the connection can bend or
damage the pins in the connector inside the chassis.
8 Snap the handles forward to secure the RTM module in the
slot.
9 Secure the RTM module screws.
Caution Blank faceplates and cover panels serve three important functions:
they prevent exposure to hazardous voltages and currents inside the chassis;
they contain electromagnetic interference (EMI) that might disrupt other
equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all blades, faceplates, front covers, and rear covers
are in place.